MATERIAL: SILICONE
CABLE TYPE: SINGLE CORE
N2GFAF (N)2GFAF
Lighting technology cables
Flexible tinned copper
Certifications
Applications
Lighting technology cables
Type of electrical conductor
Flexible tinned copper
Main rule
VDE 0250 TEIL 502
Conductor
EN 60228; IEC 60228
Cable marking
N2GFAF - (N)2GFAF ELETTRO BRESCIA <VDE> Reg. Nr. 7874
Sections
Nominal section | Max wire diameter | Conductor diameter | Insulation thickness | Average sheath thickness | Average diameter ± 0,2 | Copper electric resistance 20°C | Indicative weight |
CU Factor |
(N x mm²) | (mm) | (mm) | (mm) | (mm) | (mm) | (Ω/km) | (kg/km) | (kg/km) |
1x0,50 | 0,21 | 0,859 | 0,60 | - | 2,2 | 40,10 | - | 4,8 |
1x0,75 | 0,21 | 1,052 | 0,60 | - | 2,4 | 26,70 | - | 7,2 |
1x1,00 | 0,21 | 1,215 | 0,60 | - | 2,5 | 20,00 | - | 9,6 |
1x1,50 | 0,26 | 1,485 | 0,70 | - | 3,0 | 13,70 | - | 14,4 |
1x2,50 | 0,26 | 1,918 | 0,80 | - | 3,6 | 8,21 | - | 24 |
Documents:
Certificate |